Changing timestamp settings for XTS PCAM3000 - Security Center 5.7 SR2

Security Center Video Unit Configuration Guide 5.7 SR2

Applies to
Security Center 5.7 SR2
Last updated
2018-04-04
Content type
Guides
Guides > User guides
Language
English (United States)
Product line
Security Center unified platform > Security Center
Version
5.7

To ensure that you have the correct timestamp when you import XTS PCAM3000 video files, you must modify the OfflineDriverConfiguration.xml file on the Archiver role machine for the unit.

Procedure

  1. On the Archiver role computer, navigate to C:\Program Files (x86)\Genetec Security Center 5.3\Extensions\Drivers, and open the OfflineDriverConfiguration.xml file.
  2. Change the AssumeDateAsLocal parameter from "false" to "true".
    <OfflineDriverConfiguration>
       <AssumeDateAsLocal>true</AssumeDateAsLocal>
    </OfflineDriverConfiguration>
  3. Save the file, and restart the Archiver role.

    The import timestamp on your video files should now be accurate.