The Bosch Divar 700 can have a maximum of six recording profiles that you can use with the enabled cameras.

What you should know

There can only be one active recording profile at a time. The selected profile is used for every camera connected to the Divar.

Procedure

  1. Open the Bosch Divar 700’s web page.
  2. Click Configuration > Recording.
  3. Click a Profile tab.
  4. Click the numbered tab corresponding to the cameras connected to the Divar.
  5. Do one of the following:
    • To record continuously or on a schedule:
      1. Click the Normal tab.
        NOTE: The Normal tab determines the Divar recording settings when that profile is active. The resolution and frame rate settings cannot be configured in the Normal tab; they will be overridden by the recording settings configured in Security Center.
      2. Select a Normal recording mode (Continuous rec. or Events only).
      3. From the Quality drop-down list, select a recording quality value. This setting will affect the quality and bandwidth of the video streams coming from the Divar to Security Center.
    • To record on contact:
      NOTE: If recording on contact is selected, the recording settings configured on the Divar will override the Security Center settings.
      1. Click the Contact tab.
      2. Select a Contact recording mode (Follows, Follows + post, or Fixed duration).
      3. Select the Duration, Resolution, Quality, and Frame rate for the recording stream.
    • To record on motion:
      NOTE: If recording on motion is selected, the recording settings configured on the Divar will override the Security Center settings.
      1. Click the Motion tab.
      2. Set the Motion recording mode to Fixed duration.
      3. Select the Duration, Resolution, Quality, and Frame rate for the recording stream.
  6. Repeat the steps for each recording profile you want to create, and for each unit using that profile.
  7. To set when each recording profile is active, click Configuration > Schedule > Schedule from the Divar’s home page.
  8. Select a profile, and set the date and time that profile should record.
    NOTE: These schedules are independent of Security Center schedules.