MVIDIPv4 units sometimes develop offset start codes in the MPEG-4 video stream. As a
solution, the MPEG-4 start code lookup value must be increased so that the video stream will
be found in Security
Center.
What you should know
The MPEG-4 start code lookup advanced setting must be modified on the Client and
Server machines for proper archiving and video decoding.
Procedure
-
From the Video task in Config
Tool, select the Archiver to
configure.
-
Click the
Resources
tab.
-
In the
Resources
tab, click Advanced settings.
-
In the
Advanced settings
dialog box, click Additional settings.
-
In the Additional settings dialog box, click
.
-
In the Name column, type
Mpeg4DemuxStartCodeLook.
-
In the Value column, type 100.
-
Click Close.
-
In the
Advanced settings
dialog box, click .
-
When you are asked to restart the Archiver, click Yes.