To receive input pin events from Mango DSP units in Security
Center when the unit is managed by two Archiver
roles, the second Archiver role requires a specific configuration.
Procedure
-
On the second Archiver role machine, navigate to the installation directory,
located in C:\Program Files\Common Files\DVR Software
5.2\Extensions\Drivers\ on 32-bit machines, and C:\Program
Files (x86)\Common Files\DVR Software 5.2\Extensions\Drivers\ on 64-bit
machines.
-
Open the Generic01DriverConfiguration.xml file in
Notepad.
Text similar to the following is
displayed:
<MangoDspDriverConfiguration>
<HttpServerNumber>1</HttpServerNumber>
</MangoDspDriverConfiguration>
-
Change the value of the HttpServerNumber from
1 to 2.
-
Save the file, and restart the Archiver.