You must configure certain settings on the unit's web page before adding Interlogix
TruVision units to Security Center.
What you should know
This procedure applies to most Interlogix TruVision units, such as TVD-5303 and
TVD-3104.
Procedure
To set the video type:
-
Open the unit's web page.
-
Click .
-
From the Video Type drop-down list, select
Video&Audio for the following Stream Types:
To set the capture mode:
-
Open the unit's web page.
-
Click .
-
Under Video Adjustment, select the desired capture mode
from the Capture Mode drop-down list.
NOTE: The Capture Mode is set to OFF on
the unit's web page by default.
Certain units such as TVD-3104 have no capture mode.
To set the unit hardware motion:
-
Open the unit's web page.
-
Click .
-
Select the Enable Motion Detection check box.
-
Set the Configuration field to
Advanced.
-
Draw the motion area by selecting Draw Area.
(Optional) To set the audio output:
-
Open the unit's web page.
-
Click Live View.
-
To use the camera's Audio output, click the Live view microphone icon at the bottom
right corner.