To receive input pin events from Mango DSP units in Security Center when the unit is managed by two Archiver
roles, the second Archiver role requires a specific configuration.
Procedure
-
On the Archiver role machine, navigate to the installation directory, for example,
C:\Program Files\Common Files\DVR Software
x.x\Extensions\Drivers\ on 32-bit machines, and C:\Program
Files (x86)\Common Files\DVR Software x.x\Extensions\Drivers\ on 64-bit
machines.
x.x refers to the Security Center version.
-
Open the Generic01DriverConfiguration.xml file in
Notepad.
Text similar to the following is
displayed:
<MangoDspDriverConfiguration>
<HttpServerNumber>1</HttpServerNumber>
</MangoDspDriverConfiguration>
-
Change the value of the
HttpServerNumber
from
1 to 2.
-
Save the file and restart the Archiver.