Configuring the WV-SPN6R481 RS-485 output unit - Security Center 5.9.4.0

Security Center Video Unit Configuration Guide 5.9.4.0

Applies to
Security Center 5.9.4.0
Last updated
2022-02-18
Content type
Guides
Guides > User guides
Language
English
Product
Security Center
Version
5.9

When you attach the WV-SPN6R481 RS-485 output unit to a WV-SPN631 or WV-SPN611 camera, you must configure the RS-485 serial port on the camera's web page.

Before you begin

Install the WV-SPNR481 output unit on the back of your camera. For more information, see your Sony documentation.

Procedure

  1. Open the web page for the camera that has the WV-SPN481 attached (WV-SPN631 or WV-SPN63).
  2. Click Setup > Extension unit, then click the Back unit tab.
  3. Enter the following settings:
    RS485 transmission
    On
    Communication method
    4-line
    Baud rate
    9600bps
    Data bit
    8bit
    Parity check
    None
    Protocol
    Pelco D or Pelco P
    Unit address
    01 (for Pelco D) or 02 (for Pelco P)
  4. Add the unit in Security Center.