To use the March Networks MegaPX PTZ dome unit, you must first configure the transaction timeout in Security Center to ensure the unit does not go offline.

What you should know

If you do not configure the transaction timeout value, the timeout will default to 10 seconds.

Procedure

  1. From the Video task in Config Tool, select the Archiver to configure.
  2. Click Video unit ().
    The Manual add dialog box opens.
  3. From the Manufacturer drop-down list, select ONVIF and from the Product type list, select All.
  4. In the HTTP port field, enter 8000 and click Add.
  5. Click the Extensions tab, and click the Generic Plus extension.
  6. Set the Transaction timeout to 30 seconds.
  7. At the bottom of the Extensions tab, click Advanced settings.
  8. In Advanced settings, click .
  9. In the Name column, type WcfSendTimeout.
  10. In the Value column, type 60000.
  11. Click Close > Apply.