If you are using two LPR Processing Units on the same network, you must change the
default IP address on one of the units using the Sharp
Portal so that there is no conflict created by
duplicate IP addresses.
What you should know
If you are only using one LPR Processing Unit on the network, you do not have to
change any of the default settings. There will only be a conflict of IP addresses if you
are using two units on the same network, sometimes referred to as "daisy-chaining."
You
only have to change the IP address on one of the SBC’s. The remaining IP addresses will
automatically adjust in sequence:
Procedure
-
Connect your laptop to one of the LAN ports (LAN1 or LAN2) on the LPR Processing
Unit you want to configure.
-
Log on to the Sharp
Portal using the
IP address 192.168.10.1 for SBC1, or 192.168.10.2 for SBC2.
- If you are connected to SBC1: If you change the IP address 192.168.10.11, the
remaining components will increment by one (SBC2 will become 192.168.10.12,
GVP1 will become 192.168.10.13, and so on).
- If you are connected to SBC2 (X2S only). If you change the IP address to
192.168.10.12, SBC1 will become 192.168.10.11, and the remaining components
will increment by one (GVP1 will become 192.168.10.13, GVP2 will become
192.168.10.14, and so on).
-
Go to the Configuration page.
-
Under Network settings, click Edit,
then select Static and change the IP address.
-
If applicable, change the Subnet mask and
Gateway.
If the new IP address you choose for the camera has a different subnet, change the Subnet mask.
-
Restart the camera.
Results
This resolves all IP address conflicts, ll IP address conflicts are resolved, and you
can proceed with configuring your system.