The following table lists the standard features for all Security Center intrusion detection integrations. For each feature, one of the following is shown:
Yes
Feature is offered by the intrusion panel, and is available in Security Center.
No
Feature is offered by the intrusion panel, but is unavailable in Security Center.
Not applicable
Feature is not offered by the intrusion panel.
Feature Supported
Communications
Serial connection Not applicable No
TCP/IP connection Yes Yes
Data encryption over TCP/IP Yes (XR500E, XR550N, XR550NE), some parts of data are encrypted, such as user information, PIN, and credentials Not applicable
Status monitoring
Report online and offline status of intrusion detection units in real time Yes Yes
Intrusion detection area states Master armed Yes Yes
Perimeter armed No Yes
Alarm silenced Yes Yes
Disarmed Yes Yes
Ready-to-arm Yes Yes
Intrusion alarm active Yes Yes
Input trouble Yes Yes
Entry delay Yes No
Near real-time status monitoring of inputs and outputs   Yes Yes
Input entity states Normal Yes Yes
Active Yes Yes
Trouble Yes Yes
Alarm Yes Yes
Bypassed Yes Not applicable
Event reporting    
Report events from offline units automatically upon reconnection Yes No
Intrusion detection unit events Unit connected Yes Yes
Unit lost Yes Yes
AC fail Yes Yes
Battery fail Yes No
Tamper Yes No
Intrusion detection area events Master armed Yes Yes
Perimeter armed No Yes
Disarmed Yes Yes
Auto-arming postponed No No
Forced arming Yes No
Duress Yes. Duress corresponds to the Ambush event received from the panel. Not applicable
Entry delay started Yes No
Intrusion alarm silenced Yes Yes
Intrusion alarm activated Yes Yes
Controlling units and devices  
Trigger alarms on intrusion detection areas No Yes
Silence alarms from intrusion detection areas Yes Yes
Acknowledge alarms from intrusion detection areas No Yes
Arm areas Instant master No Yes
Delayed master Yes No
Arming delay (Override default delay) No No
Instant perimeter No Yes
Delayed perimeter No No
Forced Yes No
Bypass Yes No
Bypass inputs Yes Not applicable
Trigger outputs on intrusion detection units Yes Yes (requires a ROM device)
Configuration
Authentication between intrusion detection unit and Intrusion Manager role Yes Yes
Create intrusion detection areas automatically Yes No
Create input entities automatically Yes Yes
Create output entities automatically Yes Yes
Link input entities to intrusion detection areas automatically Yes No
Associate custom events to incoming PIN events No Not applicable
Keep clock on panel synchronized with Security Center Yes Not applicable
Link cardholders to users on the intrusion detection unit Yes (Only available with Synergis™ Professional or Enterprise packages) No
Modify user PIN credentials Yes (Only available with Synergis™ Professional or Enterprise packages) Not applicable