To learn which Security Center intrusion detection features are supported with the Southwest Microwave RPM II integration, you can view a list of supported features.
The following table lists the standard features for all
Security Center intrusion detection integrations.
For each feature, one of the following is shown:
- Yes
- Feature is offered by the intrusion panel and is available in Security Center.
- No
- Feature is offered by the intrusion panel, but is unavailable in Security Center.
- Not applicable
- Feature is not offered by the intrusion panel.
Feature | Supported | |
---|---|---|
Communications | ||
Serial connection | No | |
TCP/IP connection | Yes | |
Data encryption over TCP/IP | Not applicable | |
Status monitoring | ||
Report online and offline status of intrusion detection units in real time | Yes | |
Intrusion detection area states | Master armed | Yes |
Perimeter armed | Yes | |
Alarm silenced | Yes | |
Disarmed | Yes | |
Ready-to-arm | Yes | |
Intrusion alarm active | Yes | |
Input trouble | Yes | |
Entry delay | No | |
Near real-time status monitoring of inputs and outputs | Yes | |
Input entity states | Normal | Yes |
Active | Yes | |
Trouble | Yes | |
Alarm | Yes | |
Bypassed | Not applicable | |
Event reporting | ||
Report events from offline units automatically upon reconnection | No | |
Intrusion detection unit events | Unit connected | Yes |
Unit lost | Yes | |
AC fail | Yes | |
Battery fail | No | |
Tamper | No | |
Intrusion detection area events | Master armed | Yes |
Perimeter armed | Yes | |
Disarmed | Yes | |
Auto-arming postponed | No | |
Forced arming | No | |
Duress | Not applicable | |
Entry delay started | No | |
Intrusion alarm silenced | Yes | |
Intrusion alarm activated | Yes | |
Controlling units and devices | ||
Trigger alarms on intrusion detection areas | Yes | |
Silence alarms from intrusion detection areas | Yes | |
Acknowledge alarms from intrusion detection areas | Yes | |
Arm areas | Instant master | Yes |
Delayed master | No | |
Arming delay (Override default delay) | No | |
Instant perimeter | Yes | |
Delayed perimeter | No | |
Forced | No | |
Bypass | No | |
Bypass inputs | Not applicable | |
Trigger outputs on intrusion detection units | Yes (requires a ROM device) | |
Configuration | ||
Authentication between intrusion detection unit and Intrusion Manager role | Yes | |
Create intrusion detection areas automatically | No | |
Create input entities automatically | Yes | |
Create output entities automatically | Yes | |
Link input entities to intrusion detection areas automatically | No | |
Associate custom events to incoming PIN events | Not applicable | |
Keep clock on panel synchronized with Security Center | Not applicable | |
Link cardholders to users on the intrusion detection unit | No | |
Modify user PIN credentials | Not applicable |