Supported features for a Southwest Microwave RPM II integration - Southwest Microwave RPM II 3.0

Southwest Microwave RPM II Intrusion Detection Extension Guide 3.0

Applies to
Southwest Microwave RPM II 3.0
Last updated
2023-07-20
Content type
Guides > Plugin and extension guides
Language
English
Product
Southwest Microwave RPM II
Version
3.0

To learn which Security Center intrusion detection features are supported with the Southwest Microwave RPM II integration, you can view a list of supported features.

The following table lists the standard features for all Security Center intrusion detection integrations. For each feature, one of the following is shown:
Yes
Feature is offered by the intrusion panel and is available in Security Center.
No
Feature is offered by the intrusion panel, but is unavailable in Security Center.
Not applicable
Feature is not offered by the intrusion panel.
Feature Supported
Communications
Serial connection No
TCP/IP connection Yes
Data encryption over TCP/IP Not applicable
Status monitoring
Report online and offline status of intrusion detection units in real time Yes
Intrusion detection area states Master armed Yes
Perimeter armed Yes
Alarm silenced Yes
Disarmed Yes
Ready-to-arm Yes
Intrusion alarm active Yes
Input trouble Yes
Entry delay No
Near real-time status monitoring of inputs and outputs   Yes
Input entity states Normal Yes
Active Yes
Trouble Yes
Alarm Yes
Bypassed Not applicable
Event reporting    
Report events from offline units automatically upon reconnection No
Intrusion detection unit events Unit connected Yes
Unit lost Yes
AC fail Yes
Battery fail No
Tamper No
Intrusion detection area events Master armed Yes
Perimeter armed Yes
Disarmed Yes
Auto-arming postponed No
Forced arming No
Duress Not applicable
Entry delay started No
Intrusion alarm silenced Yes
Intrusion alarm activated Yes
Controlling units and devices  
Trigger alarms on intrusion detection areas Yes
Silence alarms from intrusion detection areas Yes
Acknowledge alarms from intrusion detection areas Yes
Arm areas Instant master Yes
Delayed master No
Arming delay (Override default delay) No
Instant perimeter Yes
Delayed perimeter No
Forced No
Bypass No
Bypass inputs Not applicable
Trigger outputs on intrusion detection units Yes (requires a ROM device)
Configuration
Authentication between intrusion detection unit and Intrusion Manager role Yes
Create intrusion detection areas automatically No
Create input entities automatically Yes
Create output entities automatically Yes
Link input entities to intrusion detection areas automatically No
Associate custom events to incoming PIN events Not applicable
Keep clock on panel synchronized with Security Center Not applicable
Link cardholders to users on the intrusion detection unit No
Modify user PIN credentials Not applicable