Resolved issues in Streamvault - The following issues are resolved in Streamvault™. - SV-100E| SV-300E| SV-300E-T4| SV-350E| SV-1000E| SV-2000E| SV-4000E| SV-4000EX| SV-7000EX| SVW-100E| SVW-300E| SVW-500E| SVR-300A| SVR-300AR| SVR-500A

Streamvault™ Appliance Release Notes

Product
Streamvault
Content type
Release notes
ft:locale
en-US
Last updated
2025-11-14

The following issues are resolved in Streamvault™.

Issue First reported in Description
465198
  • All WS.2022.1.5xx.03.S images
  • All 10.2021.1.5xxx.01.S images
After re-imaging an expansion server with this image, it's not possible to connect to a directory server from Server Admin. The Change password button is missing. For information about the expansion server page, see Server Admin - Expansion server page.
Workaround: In Server Admin, click Actions > Activate beside the server name to convert the server to the main server. Then, click Actions > Deactivate to convert the server back to the expansion server.
This issue is fixed in the following image versions:
  • WS.2022.1.5xx.04.S and later
  • 10.2021.2.5xx.02.S and later
435728 SV Control Panel 3.2.1 A DLL conflict causes both Config Tool and Security Desk to crash during loading.
436519 SV Control Panel 3.3 The removable drive setting can't be changed for the Operator account.

This issue is fixed in SV Control Panel 3.4.

349329 Streamvault Maintenance plugin 2.0.4 The root area for the plugin is not defined in Security Center 5.11.