You can configure a Streamvault™ manager entity to control the alert configurations of
a group of Streamvault™ hardware monitors from a single location. You can also set up
notifications to be raised when problems occur. Using the Streamvault manager entity is
optional.
Before you begin
NOTE: The Streamvault manager entity can run on any server (Streamvault or non-Streamvault) or
VM in your Security Center system. Only one Streamvault manager entity can be added to the
system.
Procedure
-
In Config Tool, navigate to the Plugins task and select the
Streamvault plugin role.
-
Right-click the Streamvault plugin role and click Create
manager.
-
Select the Streamvault manager entity and click the General
tab.
The following sections are displayed:
- The iDRAC alert configuration profile section manages
iDRAC-enabled servers in your system.
- The Non-iDRAC alert configuration profile section is used to
manage other non-iDRAC servers in the system.
Both sections are always shown, regardless of whether you have an iDRAC or a
non-iDRAC system.
-
(If applicable) In the iDRAC alert configuration profile section,
configure the following:
-
To manage iDRAC alert configurations through the Streamvault hardware monitor of
the selected server, select the Hardware monitor manages iDRAC alert
configurations checkbox.
-
Select the checkboxes that correlate with the Events,
Severity levels, and Notification
types that you want to apply to the Streamvault Maintenance plugin instances
controlled by the Streamvault manager.
NOTE: Hardware monitors that have their configurations set by the Streamvault
manager are listed under Hardware monitors using Streamvault™ manager
configuration. Hardware monitors that use their own configurations
are listed under Hardware monitors using custom
configuration.
-
(If applicable) In the Non-iDRAC alert configuration profile
section, configure the following:
-
Select the checkboxes that correlate with the Events and
Notification types that you want to apply to the Streamvault Maintenance plugin instances controlled by the Streamvault
manager.
-
Under Configuration, set the wear Threshold
% of the solid-state drive (SSD) at which you want to receive a
notification to inform you to replace the SSD soon.
NOTE: Hardware monitors that have their configurations set by the Streamvault
manager are listed under Hardware monitors using Streamvault™ manager
configuration. Hardware monitors that use their own configurations
are listed under Hardware monitors using custom
configuration.
-
In the Email recipients section, choose which users and user
groups receive email notifications when a condition in the iDRAC alert
configuration profile or Non-iDRAC alert configuration
profile section is met.
-
Click Apply.