Configuring unit-wide parameters in Synergis™ Softwire 10.10 - Synergis™ Softwire 10.10

Synergis™ Appliance Configuration Guide 10.10

Applies to
Synergis™ Softwire 10.10
Last updated
2019-11-11
Content type
Guides
Guides > Administrator guides
Language
English (United States)
Product line
Synergis > Synergis™ Softwire
Version
10.10

Most interface module behaviors, such as lock relays and reader settings, are common to all interface modules connected to the same Synergis™ unit. You configure these unit-wide settings on the Unit-wide parameters page.

What you should know

Some settings only apply to certain types of interface modules and are not shown unless those interface modules are configured for your unit. Whenever an equivalent setting is found in Security Center, the setting configured in Config Tool (door properties, for example) takes precedence.

For more information about these access control settings, or about how to configure them in Security Center, see Configuring access control unit settings.

Procedure

  1. Log on to the Synergis™ unit.
  2. Click on Configuration > Unit-wide parameters.
  3. In the Unit-wide parameters page, select which of the following options you want the Synergis™ unit to support:

    Door configuration

    Lock relay
    This setting tells the Synergis™ unit to do one of the following:
    After door opened
    Keep the door unlocked for a certain delay (HH:MM:SS) after the door opens.
    When door closed
    Immediately lock the door after it closes.

    Area configuration

    Interlock setting
    An interlock is a system with multiple doors where only one door can be opened at any time. You have two options:
    Single door open (Default)
    The moment one door is open, immediately lock all other doors.
    Single door unlock
    Only unlock one door at any given time.
    Automatically reset people count
    Reset people count daily or weekly. Disabled by default.

    Credential configuration

    Reader setting
    Applies to card and PIN readers only. You have two options:
    Card or PIN
    Either the card or the PIN can be used to grant access.
    Card only (Default)
    Only the card is used to grant access.
    NOTE: To enforce Card and PIN so that both the card and the PIN must be used to gain access, there is nothing to do in this area; you need to configure the settings of the reader in Config Tool.
    Maximum PIN length
    Applies to interface modules that support option-00 readers. The Synergis™ unit will process the PIN being entered the moment it reaches the maximum number of digits, without waiting for the ‘#’ key.
    NOTE: There might be exceptions; check the features of your specific integration.
    Degraded mode (VertX)
    In degraded mode, the interface module makes decisions on its own when the connection to the Synergis™ unit is lost. When this option is selected, the interface module unlocks the doors for all credentials that match the specified Facility code (26 bits card format only) instead of requiring a full match.This option applies only to Mercury and HID VertX sub-panels.
  4. Click Save.

Results

All changes become effective only after a software restart.