About support for distinct door modes in the Allegion Schlage wireless lock integration - Synergis™ Softwire 11.3

Synergis™ Appliance Configuration Guide 11.3

Applies to
Synergis™ Softwire 11.3
Last updated
2022-09-27
Content type
Guides > Administrator guides
Language
English
Product
Synergis™ Softwire
Version
11.3

The supported door modes suit a wide selection of access control contexts, but do not support the toggle credential.

Requirements

The following minimum versions are required:
  • Synergis™ Softwire 10.10 GA for the Legacy LE locks.
  • Synergis™ Softwire 11.2 GA for model B of the LE and NDE lock.
  • Security Center 5.7 SR5.

Door modes and their functions

The following supported door modes are configured through the Door mode numeric custom field on the door in Config Tool:
  • 0 - Normal operation
  • 1 - Classroom: This mode is not supported
  • 2 - Office: Press button to unlock and relock
  • 3 - Privacy: Press button to deny all access from outside, press button or REX out to deactivate
  • 4 - Apartment: Press button or REX out to unlock, stays unlocked until button press or swipe to relock
Edit custom field dialog box in Config Tool showing the Door mode custom field.