Enabling passage mode on Assa Abloy IP locks - Synergis™ Softwire 11.3

Synergis™ Appliance Configuration Guide 11.3

Applies to
Synergis™ Softwire 11.3
Last updated
2022-09-27
Content type
Guides > Administrator guides
Language
English
Product
Synergis™ Softwire
Version
11.3

To enable passage mode on doors controlled by Assa Abloy IP locks, you must create a Boolean custom field named PassageMode for either doors or access rules.

Procedure

To enable the passage mode feature per door:

  1. In Config Tool, create a Boolean type custom field for door entities, and name it PassageMode.
    NOTE: Spell the name exactly as it is written, with capital and lowercase letters.
  2. Open the Area view task.
  3. From the entity browser, select a door, and then click the Custom fields tab.
  4. Select the PassageMode custom field, and then click Apply.
  5. Repeat the previous two steps for all doors on which you want passage mode enabled.

To enable the passage mode feature per access rule:

  1. Log on to the Synergis™ unit.
  2. Click Configuration > Downstream controller settings.
  3. In the Assa Abloy IP lock settings section, select the Enable passage mode per access rule option.
  4. Click Save.
  5. Restart your Synergis™ unit.
    The PassageMode custom field for access rules is automatically created in Security Center.
  6. From the Config Tool home page, open the Access control task, and click the Access rules view.
  7. From the entity browser, select an access rule, and then click the Custom fields tab.
  8. Select the PassageMode custom field, and then click Apply.
  9. Repeat the previous two steps for all access rules on which you want passage mode enabled.