The door modes supported by Allegion Schlage AD, Legacy LE, and Legacy NDE-series locks suit a wide selection of access control contexts.

Requirements

The following minimum versions are required:
  • Synergis™ Softwire 10.6 GA.
  • Security Center 5.7 SR1 for LE locks.
  • Mercury EP firmware 1.25.6 or Mercury LP firmware 1.29.0 or later for full functionality of Apartment mode.

Door modes and their functions

The following supported door modes are configured through the Door mode numeric custom field on the door in Config Tool:
  • 0 - Normal operation
  • 1 - Classroom: Two swipes (within 5 seconds) by the same card unlocks the door until the same action locks it again
  • 2 - Office: Press button to unlock and relock
  • 3 - Privacy: Press button to deny all access from outside, press button or REX out to deactivate
  • 4 - Apartment: Press button or REX out to unlock, stays unlocked until button press or swipe to relock
Edit custom field dialog box in Config Tool showing the Door mode custom field.
Limitation: Locks that are not set to mode 0 have the following limitations:
  • Card and PIN and DoubleSwipe do not work
  • Unlock schedules and Lockdown might not work properly