The supported door modes suit a wide selection of access control contexts, but do not support the toggle credential.
Requirements
The following minimum versions are required:
- Synergis™ Softwire 10.10 GA for the Legacy LE locks.
- Synergis Softwire 11.2 GA for model B of the LE and NDE lock.
- Security Center 5.7 SR5.
Door modes and their functions
The following supported door modes are configured through the Door
mode numeric custom field on the door in Config Tool:
- 0 - Normal operation
- 1 - Classroom: This mode is not supported
- 2 - Office: Press button to unlock and relock
- 3 - Privacy: Press button to deny all access from outside, press button or REX out to deactivate
- 4 - Apartment: Press button or REX out to unlock, stays unlocked until button press or swipe to relock