You must add BEST Wi-Q locks and wireless access controllers to the gateway in Config Tool.
Before you begin
Pair the BEST Wi-Q locks or wireless access controllers with the BEST Wi-Q gateway, and
then assign them ACR (access control reader) IDs from the web page of the BEST Wi-Q gateway,
so that they can be added in Config Tool. For
more information about pairing devices to the gateway, see the BEST Wi-Q
documentation.
Procedure
-
From the Config Tool homepage, open the
Access control task.
-
Click Roles and units, and then click the Synergis™ unit.
-
Click the Peripherals tab, and then double-click the Mercury
LP4502 controller.
-
In the dialog box that opens, double-click the BEST Wi-Q gateway in the
Interfaces list.
-
In the dialog box that opens, click Add an item () under the
Interfaces list.
A dialog box opens with BEST Wi-Q Lock selected as the
Model. This option is used for locks and wireless access
controllers.
-
Enter the Door lock number for the lock or WAC, and then click
OK.
NOTE: The door lock number must match the ACR ID that was assigned to the lock or WAC on
web page of the BEST Wi-Q gateway.
-
Click .
-
Click Apply.
Results
The Mercury controller, BEST Wi-Q gateway, and locks are displayed on the
Peripherals page.
On the web page of the BEST Wi-Q gateway, the status of the lock or WAC you added in
Config Tool turns green.
After you finish
Assign the lock or WAC I/Os to doors in Config Tool. You can use the
Card In, Rex Out
door template to speed up configuration.
Example: The following image shows a
typical configuration on a door's
Hardware page.