Configuring supervised inputs on secure I/O modules - To configure a supervised input on a secure I/O module, you must first configure the input as 4 state supervised in Config Tool, then configure the resistance values on the Hardware page of the Synergis™ Appliance Portal . - Synergis Softwire 11.6.0

Synergis™ Appliance Configuration Guide 11.6.0

Product
Synergis Softwire
Content type
Guides > Administrator guides
Version
11.6
Release
11.6.0
ft:locale
en-US
Last updated
2024-11-05

To configure a supervised input on a secure I/O module, you must first configure the input as 4 state supervised in Config Tool, then configure the resistance values on the Hardware page of the Synergis™ Appliance Portal .

Before you begin

Create an OSDP channel.

Procedure

  1. From the hardware tree, select the secure I/O module you added while creating the OSDP channel and click Edit ().
  2. In the Properties dialog box, enter the Physical address for the module.
    Properties dialog box for secure I/O modules in the Synergis Appliance Portal .
  3. Click Save.
  4. Connect to Security Center with Config Tool.
  5. From the Config Tool homepage, open the Access control task, and click the Roles and units view.
  6. From the entity tree, select the Synergis unit to which the secure I/O module is connected.
  7. Click the Peripherals tab and expand the secure I/O module you want to configure.
  8. Double-click the input that you want to configure.
  9. In the Edit input dialog box, set the Contact type to 4 state supervised.
  10. Select Normally open or Normally closed as required and click Save.
    The bus takes about 5 seconds to reset.
  11. If you have more inputs to supervise, repeat steps 8 - 10.
  12. Click the Portal tab and click Configuration > Hardware.
  13. In the Inputs section, configure the supervised inputs with their correct resistance values.
  14. Click Save.