Disabling output controls on the Synergis unit - To prevent doors from being unlocked through the Synergis™ Appliance Portal , you can disable the control of output states. - Synergis Softwire 11.6.0

Synergis™ Appliance Configuration Guide 11.6.0

Product
Synergis Softwire
Content type
Guides > Administrator guides
Version
11.6
Release
11.6.0
ft:locale
en-US
Last updated
2024-11-05

To prevent doors from being unlocked through the Synergis™ Appliance Portal , you can disable the control of output states.

What you should know

  • If you disable output controls, you can view the output states, but can no longer change them on the I/O diagnostics page.
  • You can only re-enable output controls by running a DIP switch command on the Synergis™ appliance.

Procedure

  1. Log on to the Synergis unit.
  2. Click Configuration > Unit-wide parameters.
  3. In the Output controls section, click Disable output controls.
    Disable output controls button in the Output controls section of the Unit-wide parameters page in the Synergis Appliance Portal.
    The Output controls dialog box opens and prompts you to proceed.
  4. Click OK.

Results

The Disable output controls button disappears, and the following message is displayed: Output controls have been disabled.