Creating a channel to configure OSDP devices in the Synergis Appliance Portal - Before adding OSDP devices to a Synergis unit, create an OSDP channel in the Synergis Appliance Portal. - Synergis Softwire 11.6.3 - Administrator guides

Synergis™ Appliance Configuration Guide 11.6.3

Product
Synergis Softwire
Content type
Guides > Administrator guides
Version
11.6
Release
11.6.3
ft:locale
en-US
Last updated
2026-11-13

Before adding OSDP devices to a Synergis unit, create an OSDP channel in the Synergis Appliance Portal.

Procedure

  1. Sign in to the Synergis unit.
  2. Click Configuration > Hardware.
  3. At the top of the Hardware column, click Add ().
  4. In the Add hardware dialog box, select OSDP as the Hardware type.
  5. Select the Channel (A, B, C, or D) .
    NOTE: If your Synergis unit has an optional expansion module, then you have additional channels. For more information, see the SY-CLOUDLINK-312 Quick Start Guide.
  6. Set the Bits per second and Physical address for the interface.
  7. From the Connection settings list, select Unencrypted.
  8. Under Interface module type, click Add.
    Add hardware dialog box showing OSDP configuration in the Synergis Appliance Portal.
  9. Click Save.
    The OSDP channel and interface are created.