Limitations in the Synergis™ Card Synchronization plugin 4.0.0 - Card Synchronization 4.0.0

Synergis™ Card Synchronization Plugin Guide 4.0.0

Product
Card Synchronization
Content type
Guides > Plugin and extension guides
Version
4.0
Release
4.0.0
Language
English
Last updated
2024-02-28

The Card Synchronization plugin 4.0.0 includes the following known limitations.

Issue Description
2685049 The following card format names are reserved as aliases for built-in card formats: Standard, H10302, H10304, H10306, Corporate1000, Corporate48Bit, Csn32bit, FascN75Bit, FascN200Bit, and Raw. None of these aliases can be used as the name of a custom card format in Security Center.
Workaround: When referencing built-in formats, make sure that the card format in your data source is identified either by its bit length, such as 26 bit Wiegand, or by one of the aliases listed above.
2495490 The HID H10302 and HID H10304 credentials are both Wiegand 37-bit credentials. If you enter "Wiegand 37 bit" as the format name, the system uses HID H10302, not HID H10304.
Workaround: To specify an HID H10304 credential, enter "H10304" as the format name.
2345340 When synchronizing credentials, the 26 Bit Wiegand credentials fail in non-English versions of Security Center because the name of the format changes in each language.
Workaround: Use the "Standard" card format.
2299156 Starting in Security Center 5.8.1.0, the Security Center SDK references native Security Center card formats differently.
Workaround: If the name of a card format in your data source is a native card format name, replace it with the related alias, as described in Card format aliases for use with Synergis™ Card Synchronization plugin.
1666830 When adding an ODBC data source for a Microsoft Access database, your ODBC drivers must use the same architecture (32-bit or 64-bit) as GenetecPlugin.exe. Otherwise, you receive a validation error.
1137316 Activation and expiration dates in data sources must be configured in the ISO 8601 format. For example, 2018-06-28T22:15:00Z.

Custom fields in Security Center using the Date data type must also be configured in the ISO 8601 format.

1059707 Entities imported through Federation™ or the Active Directory cannot be modified by the plugin. Only custom fields linked to those entities can be synchronized.