OSDP readers must have their RS-485 bit rate and address configured before they can be
used. You can configure your readers directly from the Synergis™ Appliance Portal by creating an OSDP channel with Programming
mode enabled.
What you should know
- For OSDP readers you want connected to a Mercury unit, using this procedure, followed by
setting the reader's physical
address in the Synergis™ Appliance Portal replaces
using a configuration card to set the reader's baud rate and physical address.
- When Programming mode is enabled, you can only have one online reader connected to the
RS-485 channel at a time.
Procedure
-
Log on to the
Synergis Cloud Link unit.
-
Click .
-
At the top of the Hardware column, click
Add ().
-
In the Add hardware dialog box, select OSDP
as the Hardware type.
-
Select the Channel
(1 - 4).
-
Under Interface module type, click
Add.
-
Click Save.
The channel and reader are created.
-
From the hardware tree, select the OSDP channel you created and click
Edit ().
-
From the Bit rate list, select the bit rate you want to
configure for your reader, and then select the Programming mode
check box.
If you have a configuration card, you can use it instead of
Programming
mode. See the documentation that came with your
card.
-
Click Save.