Disabling output controls on the Synergis Cloud Link unit - Synergis Cloud Link 2.1.1

Synergis™ Cloud Link Administrator Guide 2.1.1

Applies to
Synergis Cloud Link 2.1.1
Last updated
2023-04-12
Content type
Guides > Administrator guides
Language
English
Product
Synergis Cloud Link
Version
2.1

To prevent doors from being unlocked through the Synergis™ Appliance Portal, it is recommended to disable the control of output states.

What you should know

  • If you disable output controls, you can view the output states, but can no longer change them on the I/O diagnostics page.
  • You can only re-enable output controls by running a DIP switch command on the Synergis™ Cloud Link appliance.

Procedure

  1. Log on to the Synergis Cloud Link unit.
  2. Click Configuration > Unit-wide parameters.
  3. In the Output controls section, click Disable output controls.
    Disable output controls button in the Output controls section of the Unit-wide parameters page in the Synergis Cloud Link Portal.
    The Output controls dialog box opens and prompts you to proceed.
  4. Click OK.

Results

The Disable output controls button disappears, and the following message is displayed: Output controls have been disabled.
Output controls section of the Unit-wide parameters page in the Synergis™ Appliance Portal after output controls have been disabled.