Supported Synergis™ appliance features for EntraGuard integration with Synergis™ Softwire - Synergis™ Softwire 11.3

Synergis™ Softwire 11.3 Integration Guide for Keri EntraGuard Systems

Applies to
Synergis™ Softwire 11.3
Last updated
2023-10-12
Content type
Guides > Integration guides
Language
English
Product
Synergis™ Softwire
Version
11.3

Not all Synergis™ appliance features are supported with the integration of Keri EntraGuard systems.

The Keri EntraGuard integration supports the following Synergis™ Appliance Portal and Synergis™ Softwire features. For a description of these features, see Interface tour of the Synergis™ Appliance Portal.
Synergis™ Appliance Portal and firmware features Supported
Hardware configuration (pre-staging capability)1  
Manual enrollment (Add hardware dialog box) Yes
Automatic enrollment (Scan button) No
Property configuration No
Configuration cloning (Clone button) No
I/O diagnostics (live monitoring of inputs, relays, and readers) No
Interface module firmware display No
Interface module firmware upgrade Automatic
Access control behavior (Synergis™ unit-wide settings)2  
Interlock setting (Single door unlock or Single door open) No
Do not generate Door open too long events when door is unrestricted N/A
Reader setting (Card or PIN or Card only) No
Maximum PIN length in digits N/A

1 The enrollment of the NXT module must be enabled with an XML configuration file.

2 The door behavior settings are overwritten by the individual door settings configured in Security Center.