After you enroll the NXT module, you must configure the main entrance connected to the
EntraGuard module, in Security Center.
Procedure
-
From Security Center
Config Tool, open the
Logical view task.
-
Select or create the door entity representing the physical door to the building
that is controlled by EntraGuard.
The Standard grant time configured for that door should be at least 10
seconds, because EntraGuard may take up to 7 seconds to report the Door open
event to Security Center.
-
Select the
Hardware tab of the door entity.
-
Under Preferred
unit, select the Synergis
unit that is connected to the NXT module and the EntraGuard module.
-
Under Door side: CardReader (default = A), assign the
reader attached to bus 2 (Door 2- Reader) of the Keri NXT
module to Reader, and assign the device
EntraGuard-Device PostalUnlock to Request to
exit.
For instructions on how to install a postal lock, see the EntraGuard Postal
Lock Installation Application Note (P/N 0194-001).
-
Under Door side: EG Intercom (default = B), assign
the device EntraGuard-Device RemoteUnlock to
Reader.
-
Under Additional connections, do the following:
- Assign the device Door 1-Output DoorStrike to the
Door lock output relay.
- Assign the device EntraGuard-Device DoorSensor to the
Door sensor input.
- Assign the Expansion EntraGuard-Device REX to the
Request to exit input.
-
(Optional) Add more connections if
your configuration requires them.
-
Click Apply.
After you finish
If you have a side door controlled by the NXT module, then
configure the side
door.