Supported Synergis appliance features for EntraGuard integration with Synergis Softwire - Synergis Softwire 11.4

Synergis™ Softwire 11.4 Integration Guide for Keri EntraGuard Systems

Product
Synergis Softwire
Content type
Guides > Integration guides
Version
11.4
Language
English
Last updated
2024-07-17

Not all Synergis™ appliance features are supported with the integration of Keri EntraGuard systems.

The Keri EntraGuard integration supports the following Synergis™ Appliance Portal and Synergis™ Softwire features.
Synergis Appliance Portal and firmware features Supported
Hardware configuration (pre-staging capability) 1  
Manual enrollment (Add hardware dialog box) Yes
Automatic enrollment (Scan button) No
Property configuration No
Configuration cloning (Clone button) No
I/O diagnostics (live monitoring of inputs, relays, and readers) No
Interface module firmware display No
Interface module firmware upgrade Automatic
Access control behavior (Synergis unit-wide settings) 2  
Interlock setting (Single door unlock or Single door open) No
Do not generate Door open too long events when door is unrestricted Not applicable
Reader setting (Card or PIN or Card only) No
Maximum PIN length in digits Not applicable

1 The enrollment of the NXT module must be enabled with an XML configuration file.

2 The door behavior settings are overwritten by the individual door settings configured in Security Center.