To add OSDP readers to a Mercury or Synergis™ unit, configure the readers using the Synergis™ Appliance Portal.

What you should know

If you are installing OSDP readers on adjacent turnstiles, it is not recommended to connect more than two readers to the same RS-485 channel, as it increases the controller’s response time and the chance of two or more cards being presented at the same time is high. For conventional doors, you can install up to four readers per bus.

All readers connected to the same RS-485 channel must be set with different addresses.

Procedure

  1. From the hardware tree, select the OSDP reader you added while creating the OSDP channel and click Edit ().
  2. In the Properties dialog box, enter the physical address you want to set for the reader.
  3. Click Save
  4. Connect and power up the reader.
    The configured bit rate and physical address are sent to the reader, which comes online after it has accepted them.
  5. Disconnect or power down the reader.
  6. Repeat steps 1 to 5 for the remaining readers.
  7. From the hardware tree, select the OSDP channel and click Edit (), then clear the Programming mode check box that you selected while creating the channel.
  8. Add the configured readers:
    1. At the top of the Address column, click Add ().
    2. In the Add hardware dialog box, Click Add to add the readers at the addresses you've programmed.
  9. Click Save.