Enrolling DDS IP controllers - Synergis™ Softwire 11.2

Synergis™ Softwire Integration Guide 11.2

Applies to
Synergis™ Softwire 11.2
Last updated
2023-04-03
Content type
Guides > Integration guides
Language
English
Product
Synergis™ Softwire
Version
11.2

For the Synergis™ unit to communicate with the DDS controllers connected to your IP network, you must enroll them on the Synergis™ unit.

Before you begin

Make sure you have completed the following:

Procedure

  1. Log on to the Synergis™ unit.
  2. Click Configuration > Hardware.
  3. At the top of the Hardware column, click Add ().
  4. In the Add hardware dialog box, select DDS as the Hardware type.
  5. From the Channel list, select NEW (IP).
  6. In the same dialog box, add all interface modules connected to the same IP unit.
    To enroll manually, enter the physical address (0 to 31) configured on the DDS module and click Add (). Then select the exact module type. Repeat as necessary to configure all modules connected to the same IP unit.
  7. Click Save.
    The hardware type, channel, and interface module you just added are listed on the Hardware configuration page.
  8. For each interface module you added, select it from the Hardware configuration page and configure its settings.
    For the description of these settings, refer to the manufacturer’s documentation. Make the changes as needed.
  9. Click Save.