Not all Security Center access control features are supported with the integration of Aperio-enabled locks from Assa Abloy.

The Aperio-enabled lock integration supports the following Security Center access control features.
The following is the legend for some common values found in the Supported column:
Yes
Feature is supported by this integration.
Limited
Part of the feature is not supported.
No
Feature is not supported by this integration.
Online
Feature is supported only when the interface module is connected to the Synergis™ unit.
Not applicable
Feature does not apply to this integration.
Feature group Security Center feature Supported
Door behavior settings (overrides the Synergis™ unit-wide settings) Maintenance mode (keep door unlocked and ignore all access events) Yes
Standard grant time Yes
Extended grant time Yes
Entry time (Standard/Extended) No
Door relock - options No
When door is unlocked by schedule - options Yes
Door held - options Limited1
Door forced open - options Limited1
Unlock schedules Limited2
Request to exit (REX) options  
Unlock on REX (On/Off) No3
Time to ignore REX after granting access (in seconds) Yes
Ignore REX events while door is open (On/Off) Yes
Time to ignore REX after door closes (in seconds) Yes
Visitor escort and two-person rule  
Maximum delay between card presentation (in seconds) Yes
Enforce two-person rule (On/Off) on Door side Yes
Manual actions on doors in Security Desk4 Manually unlock doors v3 locks only
Reader shunting (activate/deactivate reader) Yes
Override unlock schedules Yes2
Live event monitoring in Security Desk Module running state (Online, Offline) Yes
AC fail Not applicable
Battery fail (Low battery) Yes
Door open/closed Yes
Door locked/unlocked Yes
Door forced open Yes
Door held open for too long Yes
Duress PIN Yes
Deadbolt (Secured, Released) Yes
Key override Limited5
Area restrictions (for secured areas) Minimum security clearance (part of threat level management) Yes
Visitor escort rule (On/Off) Yes
Interlock Yes
Antipassback  
Hard (log and deny access on Antipassback violation) Limited6
Presence timeout (forget area presence after a certain delay) Yes
Strict (antipassback checked on both area entrance and exit) Yes
On schedule Yes
Max occupancy Yes
Global antipassback Yes
First-person-in rule  
Enforce on door unlock schedule Yes
Enforce on access rules Yes
Elevator control Elevators Not applicable
Zone management I/O zone No
Hardware zone No

1 The Reader buzzer behavior options are not supported.

2 Update depends on Polling interval (v3 locks) or Status report interval (other than v3 locks).

3 The Unlock on REX option must always be set to OFF in Config Tool.

4 The Synergis™ unit must be connected to the Access Manager.

5 Not all Aperio-enabled locks support the key override sensor. Confirm with the manufacturer to know the exact sensors that are supported for each model.

6 Not recommended for Card-In/REX-Out doors because a cardholder's presence in the area cannot be verified.