Not all Security Center access control features are supported with the integration of Sharp cameras.

The Sharp camera integration supports the following Security Center access control features.
The following is the legend for some common values found in the Supported column:
Yes
Feature is supported by this integration.
Limited
Part of the feature is not supported.
No
Feature is not supported by this integration.
Online
Feature is supported only when the interface module is connected to the Synergis™ unit.
Not applicable
Feature does not apply to this integration.
Feature group Security Center feature Supported
Door behavior settings (overrides the Synergis™ unit-wide settings) Maintenance mode (keep door unlocked and ignore all access events) Yes
Standard grant time Yes
Extended grant time Yes
Entry time (Standard/Extended)1 Yes
Door relock - options Yes
When door is unlocked by schedule - options Yes
Door held - options Yes
Door forced open - options Yes
Unlock schedules Yes
Request to exit (REX) options  
Unlock on REX (On/Off) Yes
Time to ignore REX after granting access (in seconds) Yes
Ignore REX events while door is open (On/Off) Yes
Time to ignore REX after door closes (in seconds) Yes
Visitor escort and two-person rule  
Maximum delay between card presentation (in seconds) Not applicable
Enforce two-person rule (On/Off) on Door side Not applicable
Manual actions on doors in Security Desk2 Manually unlock doors Yes
Reader shunting (activate/deactivate reader) Yes
Override unlock schedules Yes
Live event monitoring in Security Desk Module running state (Online, Offline) Yes
AC fail Not applicable
Battery fail (Low battery) Not applicable
Door open/closed Yes
Door locked/unlocked Yes
Door forced open Yes
Door held open for too long Yes
Duress PIN No
Area restrictions (for secured areas) Minimum security clearance (part of threat level management) Yes
Visitor escort rule (On/Off) Not applicable
Interlock Yes
Antipassback  
Hard (log and deny access on Antipassback violation) Yes
Presence timeout (forget area presence after a certain delay) Yes
Strict (antipassback checked on both area entrance and exit) Yes
On schedule Yes
Max occupancy Yes
Global antipassback Yes
First-person-in rule  
Enforce on door unlock schedule Not applicable
Enforce on access rules Not applicable
Elevator control Elevators Not applicable
Zones I/O zone Yes
Hardware zone  
Zone arming input Yes
Zone arming schedule Yes
Zone arming and entry delays No
Zone I/O linking Yes
Countdown buzzer Yes

1 Security Center requires an entry sensor to accurately detect entry into an area. In the absence of the entry sensor, Security Center uses the door sensor, and the Entry detected event is generated when the door sensor is triggered. In the absence of both sensors, Security Center generates the Entry assumed event when access is granted.

2 The Synergis™ unit must be connected to the Access Manager.