Not all Security Center access control features are supported with the integration of SALTO SALLIS wireless locks.

The SALTO SALLIS wireless lock integration supports the following Security Center access control features.
The following is the legend for some common values found in the Supported column:
Yes
Feature is supported by this integration.
Limited
Part of the feature is not supported.
No
Feature is not supported by this integration.
Online
Feature is supported only when the interface module is connected to the Synergis™ unit.
Not applicable
Feature does not apply to this integration.
Feature group Security Center feature Supported
Door behavior settings (overrides the Synergis™ unit-wide settings) Maintenance mode (keep door unlocked and ignore all access events) Yes
Standard grant time No1
Extended grant time No
Entry time (Standard/Extended)2 No
Door relock - options No
When door is unlocked by schedule - options See note3
Door held - options Limited4
Door forced open - options Limited4
Unlock schedules Yes
Request to exit (REX) options  
Unlock on REX (On/Off) Not applicable
Time to ignore REX after granting access (in seconds) Yes
Ignore REX events while door is open (On/Off) Yes
Time to ignore REX after door closes (in seconds) Yes
Visitor escort and two-person rule  
Maximum delay between card presentation (in seconds) Yes
Enforce two-person rule (On/Off) on Door side Yes
Manual actions on doors in Security Desk5 Manually unlock doors Yes
Reader shunting (activate/deactivate reader) Yes
Override unlock schedules Yes
Live event monitoring in Security Desk Module running state (Online, Offline) Yes
AC fail Not applicable
Battery fail (Low battery) Yes
Door open/closed No
Door locked/unlocked No
Door forced open Yes
Door held open for too long Yes
Duress PIN No
Deadbolt (Secured, Released) Not applicable
Key override Yes
Area restrictions (for secured areas) Minimum security clearance (part of threat level management) Yes
Visitor escort rule (On/Off) Yes
Interlock No6
Antipassback No
Max occupancy No
First-person-in rule  
Enforce on door unlock schedule Yes
Enforce on access rules Yes
Elevator control Elevators Not applicable
Zone management I/O zone No
Hardware zone No7

1 Must be configured in the SALLIS application. The default value is 6 sec.

2 Security Center requires an entry sensor to accurately detect entry into an area. In the absence of the entry sensor, Security Center uses the door sensor, and the Entry detected event is generated when the door sensor is triggered. In the absence of both sensors, Security Center generates the Entry assumed event when access is granted.

3 All events are ignored when the door is unlocked.

4 The Reader buzzer behavior options are not supported.

5 The Synergis™ unit must be connected to the Access Manager.

6 Because there is no door sensor, there is no Door opened event to guide the interlock.

7 It is possible to create a hardware zone entity in Config Tool using inputs from SALLIS, but there would be a significant trigger delay.