Supported SimonsVoss locks in Synergis™ Softwire 11.3 - Synergis™ Softwire 11.3

Synergis™ Softwire Integration Guide 11.3

Applies to
Synergis™ Softwire 11.3
Last updated
2023-04-03
Content type
Guides > Integration guides
Language
English
Product
Synergis™ Softwire
Version
11.3

SimonsVoss SmartIntego lock integration requires a Mercury EP or LP (or Honeywell) controller. For this integration, the EP and LP controllers are viewed as interface modules, and the SmartIntego locks are viewed as non-intelligent devices. All SmartIntego locks are wireless.

The Mercury EP or LP (or Honeywell) controllers communicate directly with the Synergis™ unit.

Synergis™ Softwire 11.3 supports all SmartIntego models that work with Mercury IP controllers:
Model Description Minimum compatible versions
IP controllers A Mercury (or Honeywell) controller must act as an interface module between the Synergis™ unit and the SmartIntego locks.
The following controllers are supported:
  • Mercury EP1501 and LP1501 controllers with expansion board, supporting up to 16 SmartIntego locks
  • Mercury EP1502, LP1502, EP2500, LP2500, EP4502, and LP4502 controllers supporting up to 64 SmartIntego locks
  • Honeywell PW6K1IC and PRO32IC controllers supporting up to 64 SmartIntego locks

See also Supported Mercury firmware versions in Synergis™ Softwire 11.3.

  • Mercury EP1501, EP1502, EP2500, and Honeywell PW6K1IC:
    • Security Center 5.6
    • Synergis™ Softwire 10.4
  • Mercury LP1501, LP1502 and LP2500:
    • Security Center 5.8
    • Synergis™ Softwire 10.10
  • Mercury EP4502, LP4502, and Honeywell PRO32IC:
    • Security Center 5.9.0.0
    • Synergis™ Softwire 10.11
Gateway node Handles the communication between the Mercury IP controller and SmartIntego locks (Up to 16 locking devices per node through a 868 MHz wireless connection, with a range up to 30 meters.).
  • Security Center 5.6
  • Synergis™ Softwire 10.4
Programming dongle Required to pair the locks to the Gateway node.
  • Security Center 5.6
  • Synergis™ Softwire 10.4
Smart Handle Door handle/reader combo. Includes a manual REX out which cannot be monitored. May come with or without inputs.
  • Security Center 5.6
  • Synergis™ Softwire 10.4
Digital Locking Cylinder Different wireless models; some of them have two readers, but only one reader is detected by the Mercury IP controller. May come with or without inputs.
  • Security Center 5.6
  • Synergis™ Softwire 10.4
Padlock Padlock with no keyhole, only a card reader.
  • Security Center 5.6
  • Synergis™ Softwire 10.4

Limitations

  • Manual unlock and relock commands can take more time than expected to be executed. This is because these commands rely on a wireless communication that may take a few seconds to respond.
  • Only MIFARE DESFire®, and MIFARE Plus card formats are supported.