Supported Synergis™ appliance features for HID VertX sub-panel integration with Synergis™ Softwire 11.3 - Synergis™ Softwire 11.3

Synergis™ Softwire Integration Guide 11.3

Applies to
Synergis™ Softwire 11.3
Last updated
2023-04-03
Content type
Guides > Integration guides
Language
English
Product
Synergis™ Softwire
Version
11.3

Not all Synergis™ appliance features are supported with the integration of HID VertX sub-panels.

The HID VertX sub-panel integration supports the following Synergis™ Appliance Portal and Synergis™ Softwire features. For a description of these features, see Interface tour of the Synergis™ Appliance Portal.
Synergis™ Appliance Portal and firmware features Supported
Hardware configuration (pre-staging capability)  
Manual enrollment (Add hardware dialog box) Yes
Automatic enrollment (Scan button) Yes
Property configuration Yes
Configuration cloning (Clone button) Yes
I/O diagnostics (live monitoring of inputs, relays, and readers) Yes
Interface module firmware display No
Interface module firmware upgrade No
Double-badge activation Online
Access control behavior (Synergis™ unit-wide settings) 1, 2  
Interlock setting (Single door unlock or Single door open) Online
Do not generate Door open too long events when door is unrestricted Yes
Reader setting (Card or PIN or Card only) Online
Maximum PIN length in digits3 15

1 The door behavior settings are overwritten by the individual door settings configured in Security Center.

2 Only applies to VertX V100.

3 For interface modules that support HID mode-00 readers.