Supported access control features for Allegion Schlage wireless lock integration with Synergis™ Softwire 11.3 - Synergis™ Softwire 11.3

Synergis™ Softwire Integration Guide 11.3

Applies to
Synergis™ Softwire 11.3
Last updated
2023-04-03
Content type
Guides > Integration guides
Language
English
Product
Synergis™ Softwire
Version
11.3

Not all Security Center access control features are supported with the integration of Allegion Schlage wireless locks.

The Allegion Schlage wireless lock integration supports the following Security Center access control features.
The following is the legend for some common values found in the Supported column:
Yes
Feature is supported by this integration.
Limited
Part of the feature is not supported.
No
Feature is not supported by this integration.
Online
Feature is supported only when the interface module is connected to the Synergis™ unit.
Not applicable
Feature does not apply to this integration.
Feature group Security Center feature Supported
Door behavior settings (overrides the Synergis™ unit-wide settings) Maintenance mode (keep door unlocked and ignore all access events) No
Standard grant time Yes
Extended grant time Yes
Entry time (Standard/Extended) No
Door relock - options No1
When door is unlocked by schedule - options No
Door held - options Yes
Door forced open - options NDE & LE locks only
Unlock schedules NDE & LE locks only
Request to exit (REX) options  
Unlock on REX (On/Off) No
Time to ignore REX after granting access (in seconds) No
Ignore REX events while door is open (On/Off) No
Time to ignore REX after door closes (in seconds) No
Visitor escort and two-person rule  
Maximum delay between card presentation (in seconds) No
Enforce two-person rule (On/Off) on Door side No
Manual actions on doors in Security Desk2 Manually unlock doors Yes
Reader shunting (activate/deactivate reader) No
Override unlock schedules NDE & LE locks only
Live event monitoring in Security Desk Module running state (Online, Offline) Yes
AC fail Not applicable
Battery fail (Low battery) Yes
Door open/closed NDE & LE locks only
Door locked/unlocked Yes
Door forced open NDE & LE locks only
Door held open for too long NDE & LE locks only
Duress PIN No
Deadbolt (Secured, Released) Yes3
Key override No
Area restrictions (for secured areas) Minimum security clearance (part of threat level management) No
Visitor escort rule (On/Off) No
Interlock No
Antipassback  
Hard (log and deny access on Antipassback violation) No
Presence timeout (forget area presence after a certain delay) No
Strict (antipassback checked on both area entrance and exit) No
On schedule No
Max occupancy No
Global antipassback No
First-person-in rule  
Enforce on door unlock schedule No
Enforce on access rules No
Elevator control Elevators Not applicable
Zone management I/O zone No
Hardware zone No

1 Relocks after 3 seconds or on close, whichever occurs first. The set timeout is not taken into account.

2 The Synergis™ unit must be connected to the Access Manager.

3 Control and LE locks only.