Not all Security Center access control features are supported with the integration of BEST Wi-Q locks.

The BEST Wi-Q lock integration supports the following Security Center access control features.
The following is the legend for some common values found in the Supported column:
Yes
Feature is supported by this integration.
Limited
Part of the feature is not supported.
No
Feature is not supported by this integration.
Online
Feature is supported only when the interface module is connected to the Synergis™ unit.
Not applicable
Feature does not apply to this integration.
Feature group Security Center feature Supported
Door behavior settings (overrides the Synergis™ unit-wide settings) Maintenance mode (keep door unlocked and ignore all access events) Yes1
Standard grant time Yes
Extended grant time Yes
Entry time (Standard/Extended) No
Door relock - options Limited2
When door is unlocked by schedule - options Yes
Door held - options Yes3
Door forced open - options Yes3, 9
Unlock schedules Yes
Request to exit (REX) options  
Unlock on REX (On/Off) Limited4
Time to ignore REX after granting access (in seconds) No
Ignore REX events while door is open (On/Off) No
Time to ignore REX after door closes (in seconds) No
Visitor escort and two-person rule  
Maximum delay between card presentation (in seconds) No
Enforce two-person rule (On/Off) on Door side No
Manual actions on doors in Security Desk Manually unlock doors Yes1
Reader shunting (activate/deactivate reader) Yes1
Override unlock schedules Yes1
Live event monitoring in Security Desk8 Module running state (Online, Offline) Yes1
AC fail Yes
Battery fail (Low battery) Yes5
Door open/closed Yes6
Door locked/unlocked No
Door forced open Yes7
Door held open for too long Yes7
Duress PIN No
Deadbolt (Secured, Released) No
Key override Yes
Area restrictions (for secured areas) Minimum security clearance (part of threat level management) No
Visitor escort rule (On/Off) No
Interlock No
Antipassback  
Hard (log and deny access on Antipassback violation) No
Presence timeout (forget area presence after a certain delay) No
Strict (antipassback checked on both area entrance and exit) No
On schedule No
Max occupancy No
Global antipassback No
First-person-in rule  
Enforce on door unlock schedule No
Enforce on access rules No
Elevator control Elevators Not applicable
Zone management I/O zone Not applicable
Hardware zone Not applicable

1 Dependent on the beacon time configured on the web page of the BEST Wi-Q gateway. The beacon time is the polling interval of the controller and the gateway, and is 60 seconds by default. Decreasing the beacon time decreases the battery life of the lock. For example, setting the beacon time to 10 seconds can result in a battery life shorter than a month.

2 Supported on close only.

3 No pre-alarm events or reader buzzer.

4 On only. Not supported on wireless access controllers. Only the shunt fires on REX. On access grant, both the strike and shunt fire. The shunt firing time is determined by the time configured in the Door held section of the door's Properties page in Config Tool.

5 Notification for low and critical battery levels. This only applies to locks, not to wireless access controllers.

6 Only during door alarms, such as Door forced open and Door held open.

7 Changing the Program door alarm LED procedures option on the Mercury controller settings page in the Synergis™ Appliance Portal does not affect the LED behavior of BEST Wi-Q locks.

8 The timestamps of events from BEST Wi-Q controllers can be inaccurate by up to one minute. During credential synchronization from the gateway to the controller, no events are received in Security Desk because events are stored on controllers as offline events until synchronization is complete. Synchronizing 10,000 credentials can take up to 15 minutes.

9 If the Trigger event option configured in the Door held section of the door's Properties page in Config Tool is turned off, the shunt fire time defaults to 65,534 seconds.