Not all Security Center access control features are supported with the integration of HID VertX sub-panels.

The HID VertX sub-panel integration supports the following Security Center access control features.
The following is the legend for some common values found in the Supported column:
Yes
Feature is supported by this integration.
Limited
Part of the feature is not supported.
No
Feature is not supported by this integration.
Online
Feature is supported only when the interface module is connected to the Synergis™ unit.
Not applicable
Feature does not apply to this integration.
Feature group Security Center feature Supported
Door behavior settings (overrides the Synergis™ unit-wide settings)1 Maintenance mode (keep door unlocked and ignore all access events) Yes
Standard grant time Yes
Extended grant time Online
Entry time (Standard/Extended)2 Online
Door relock - options Online
When door is unlocked by schedule - options Online
Door held - options Online
Door forced open - options Online
Unlock schedules Online
Request to exit (REX) options  
Unlock on REX (On/Off) Yes
Time to ignore REX after granting access (in seconds) Online
Ignore REX events while door is open (On/Off) Online
Time to ignore REX after door closes (in seconds) Online
Visitor escort and two-person rule  
Maximum delay between card presentation (in seconds) Online
Enforce two-person rule (On/Off) on Door side Online
Manual actions on doors in Security Desk3 Manually unlock doors Online
Reader shunting (activate/deactivate reader) Online
Override unlock schedules Online
Live event monitoring in Security Desk Module running state (Online, Offline) Yes
AC fail Online
Battery fail (Low battery) Online
Door open/closed Online
Door locked/unlocked Online
Door forced open Online
Door held open for too long Online
Duress PIN Yes
Area restrictions (for secured areas) Minimum security clearance (part of threat level management) Online
Visitor escort rule (On/Off) Online
Interlock Online
Antipassback  
Hard (log and deny access on Antipassback violation) Online4
Presence timeout (forget area presence after a certain delay) Online
Strict (antipassback checked on both area entrance and exit) Online
On schedule Online
Max occupancy Online
Global antipassback Online
First-person-in rule  
Enforce on door unlock schedule Online
Enforce on access rules Online
Elevator control Elevators Online
Zone management I/O zone Online
Hardware zone Online

1 Only apply to VertX V100.

2 Security Center requires an entry sensor to accurately detect entry into an area. In the absence of the entry sensor, Security Center uses the door sensor, and the Entry detected event is generated when the door sensor is triggered. In the absence of both sensors, Security Center generates the Entry assumed event when access is granted.

3 The Synergis™ unit must be connected to the Access Manager.

4 Not recommended for Card-In/REX-Out doors because a cardholder's presence in the area cannot be verified.