Supported access control features for SimonsVoss lock integration with Synergis™ Softwire 11.3 - Synergis™ Softwire 11.3

Synergis™ Softwire Integration Guide 11.3

Applies to
Synergis™ Softwire 11.3
Last updated
2023-04-03
Content type
Guides > Integration guides
Language
English
Product
Synergis™ Softwire
Version
11.3

Not all Security Center access control features are supported with the integration of SimonsVoss locks.

The SimonsVoss lock integration supports the following Security Center access control features.
The following is the legend for some common values found in the Supported column:
Yes
Feature is supported by this integration.
Limited
Part of the feature is not supported.
No
Feature is not supported by this integration.
Online
Feature is supported only when the interface module is connected to the Synergis™ unit.
Not applicable
Feature does not apply to this integration.
Feature group Security Center feature Supported
Door behavior settings (overrides the Synergis™ unit-wide settings) Maintenance mode (keep door unlocked and ignore all access events) No
Standard grant time Yes1
Extended grant time Not applicable
Entry time (Standard/Extended)2 Not applicable
Door relock - options No
When door is unlocked by schedule - options Yes
Door held - options No
Door forced open - options Not applicable
Unlock schedules Yes
Request to exit (REX) options  
Unlock on REX (On/Off) Not applicable
Time to ignore REX after granting access (in seconds) Not applicable
Ignore REX events while door is open (On/Off) Not applicable
Time to ignore REX after door closes (in seconds) Not applicable
Visitor escort and two-person rule  
Maximum delay between card presentation (in seconds) Yes4
Enforce two-person rule (On/Off) on Door side Yes
Manual actions on doors in Security Desk3 Manually unlock doors Yes
Reader shunting (activate/deactivate reader) No
Override unlock schedules Yes
Live event monitoring in Security Desk Module running state (Online, Offline) Yes
AC fail No
Battery fail (Low battery) Yes
Door open/closed No
Door locked/unlocked No
Door forced open No
Door held open for too long No
Duress PIN No
Area restrictions (for secured areas) Minimum security clearance (part of threat level management) Not applicable
Visitor escort rule (On/Off) Yes
Interlock Not applicable
Antipassback Not applicable
Max occupancy Not applicable
First-person-in rule Not applicable
Elevator control Elevators Not applicable
Zone management I/O zone Not applicable
Hardware zone Not applicable

1 The maximum supported value is 255 seconds. Values between 26 and 59 seconds are rounded to 1 minute. Values above 60 seconds are rounded to the next minute. For example, 121 seconds is rounded to 3 minutes.

2 Security Center requires an entry sensor to accurately detect entry into an area. In the absence of the entry sensor, Security Center uses the door sensor, and the Entry detected event is generated when the door sensor is triggered. In the absence of both sensors, Security Center generates the Entry assumed event when access is granted.

3 The Synergis™ unit must be connected to the Access Manager.

4 The minimum value is five seconds. The lock LED blinks when it is ready for the second card to be presented, which is not immediately.