Supported Synergis appliance features for DDS controller integration with Synergis Softwire 11.4.2 - Synergis Softwire 11.4.2

Synergis™ Softwire Integration Guide 11.4.2

Product
Synergis™ Softwire
Content type
Guides > Integration guides
Version
11.4
Release
11.4.2
ft:locale
en-US
Last updated
2023-07-10

Not all Synergis™ appliance features are supported with the integration of DDS controllers.

The DDS controller integration supports the following Synergis™ Appliance Portal and Synergis™ Softwire features. For a description of these features, see Interface tour of the Synergis™ Appliance Portal.
Synergis™ Appliance Portal and firmware features Supported
Hardware configuration (pre-staging capability)1  
Manual enrollment (Add hardware dialog box) RS-485 only
Automatic enrollment (Scan button) RS-485 only
Property configuration RS-485 only
Configuration cloning (Clone button) RS-485 only
I/O diagnostics (live monitoring of inputs, relays, and readers) Yes
Interface module firmware display No
Interface module firmware upgrade Automatic
Double-badge activation Online
Access control behavior (Synergis unit-wide settings)2  
Interlock setting (Single door unlock or Single door open) Online
Do not generate Door open too long events when door is unrestricted Yes
Reader setting (Card or PIN or Card only) Online3
Maximum PIN length in digits4 55

1 IP controllers must be enrolled through a different set of web pages than the Synergis™ Appliance Portal. See Enrolling DDS IP controllers.

2 The door behavior settings are overwritten by the individual door settings configured in Security Center.

3 Keypad readers outputting PIN in 4-bit Burst Keypad Mode are not supported. Only PIN outputted in 26-bit Wiegand mode producing Facility Code 0 is supported.

4 Limited to HID Wiegand Standard 26-bit card code (maximum value is 65534).

5 PINs under 4 digits are not accepted.