Not all Synergis™ appliance features are supported with the integration of SALTO SALLIS wireless locks.
The SALTO SALLIS wireless lock integration supports the following Synergis™ Appliance Portal and Synergis™ Softwire features. For a description of these
features, see Interface tour of the Synergis™ Appliance Portal.
| Synergis™ Appliance Portal and firmware features | Supported |
|---|---|
| Hardware configuration (pre-staging capability) | |
| Manual enrollment (Add hardware dialog box) | Yes |
| Automatic enrollment (Scan button) | Yes |
| Property configuration | Yes |
| Configuration cloning (Clone button) | Yes |
| I/O diagnostics (live monitoring of inputs, relays, and readers) | Partial1 |
| Interface module firmware display | Router only |
| Interface module firmware upgrade | No |
| Double-badge activation | No |
| Access control behavior (Synergis unit-wide settings)2 | |
| Interlock setting (Single door unlock or Single door open) | No |
| Do not generate Door open too long events when door is unrestricted | Yes |
| Reader setting (Card or PIN or Card only) | No3 |
| Maximum PIN length in digits | Not applicable |
1 Inputs without a sensor attached are not monitored on the I/O diagnostic page.
2 The door behavior settings are overwritten by the individual door settings configured in Security Center.
3 Card and PIN is not supported.