Interface modules come in all shapes and sizes and offer a wide range of features. Synergis™ Softwire supports most of the common features found on the market.
- Yes
- Synergis Softwire supports the feature and the interface module offers it.
- No
- Synergis Softwire does not support the feature, but the interface module offers it.
- Not applicable
- The interface module does not offer the feature.
Features | Supported |
---|---|
General characteristics | |
Category of interface module | Intelligent lock |
Communication protocol | IP |
Encrypted communication | Yes |
Escape and return mode | Yes |
Passage mode | Yes1 |
Privacy mode | Yes |
Online operation (connected to the Synergis unit) | |
Standalone mode | Not applicable |
Supervised mode | Yes2 |
Dependent mode | No |
Offline operation (no connection to the Synergis unit) | |
Standalone mode | Yes |
Degraded mode | Not applicable |
Wireless operation (WiFi only) | |
Contact the Synergis unit on event | Yes3 |
Scheduled radio contact (Status report interval) | Yes4 |
Battery checks | Yes5 |
Power fail lock settings (Fail Safe/Fail Secure) | Yes6 |
Configurable Radio Wakeup events | Yes |
Scalability | |
Maximum number of offline events | 10,0007 |
Maximum number of credentials (for autonomous decision making) | 10,0008 |
Maximum credential length (in bits) | 140 |
Maximum number of interface modules per Synergis unit RS-485 channel | Not applicable |
Recommended maximum number of interface modules per Synergis unit | 128 |
1 Passage mode, or double-badge activation, is applied to all cardholders, and is not schedule-dependent.
2 The Wi-Fi lock might take up to 15 seconds to unlock for unknown credentials not yet synchronized to the lock. Badging a second time might be required.
3 By default, the Wi-Fi lock contacts the Synergis™ unit on the following events: Access denied (for any reason), Door forced open, and Door open too long.
4 The default Wi-Fi radio wake up schedule is every day at 0:00 UTC time.
5 The default battery check schedule is every day at 23:00 UTC time.
6 The default Power fail lock setting is Fail Secure, meaning the door is locked when power is off.
7 There is not always a one-to-one match between an offline log entry and a Security Center event.
8 Cx type locks only; legacy Sx and Px type locks remain at 2,400 credentials. when legacy Px locks are configured for Card and PIN, the capacity drops to 1,200 credentials.