For DDS integration, each TPL door controller is viewed as an interface module.
Synergis™ Softwire 11.4.3 supports the following DDS hardware
devices:
Model | Description | Firmware |
---|---|---|
AS34 or TPL | Door controller supporting RS-485 communication, featuring four Wiegand
readers, suitable for two card in/card out doors. NOTE: Make sure the ROM chip
installed on the U5 socket of the TPL board is labeled
5xxx1.
|
Synergis Softwire requires a custom version of the firmware. The custom firmware is automatically pushed to the TPL module during enrollment. |
AS34-P4 or TPL-P4 | Door controller supporting RS-485 communication, featuring four Wiegand
readers, suitable for four card in/REX out doors. NOTE: Make sure the ROM chip
installed on the U5 socket of the TPL board is labeled
6xxx1.
|
|
EXT-TCPT | TCP/IP extension board for the TPL door controller. | Not applicable |
EXT-8E4S | TCP/IP extension board adding 8 supervised inputs and 4 outputs to the TPL
door controller with the ROM chip 6xxx1. This combination is equivalent to adding TCP/IP interface to the TPL-P4 controller. |
Not applicable |
1The exact chip number depends on the storage capacity of the ROM.