Supported Mercury controllers in Synergis Softwire 11.4.3 - Synergis Softwire 11.4.3

Synergis™ Softwire Integration Guide 11.4.3

Product
Synergis™ Softwire
Content type
Guides > Integration guides
Version
11.4
Release
11.4.3
Language
English
Last updated
2024-04-10

In the Mercury controller integration, Mercury controllers are called interface modules because they connect the downstream panels (MR50, MR52, and so on) to the Synergis™ unit.

Mercury EP, LP, M5-IC, and M5-ICS controllers communicate directly with the Synergis unit.

Visit the Genetec™ Resource center for the datasheets of the supported Mercury devices.

Synergis™ Softwire 11.4.3 supports the following Mercury devices:
Model Description Minimum compatible versions
EP1501 and LP1501 IP controller that natively supports up to 2 readers and 1 opening. Using on-board OSDP, device controls 1 door and up to 2 OSDP multi-dropped readers. When not using on-board OSDP reader, device can expand to support up to 17 readers and openings in total.
  • EP1501:
    • Security Center 5.3 SR1
    • Synergis Softwire 10.0
  • LP1501:
    • Security Center 5.8
    • Synergis Softwire 10.10
EP1502 and LP1502 IP controller with eight inputs, four outputs, two reader connections, and one RS-485 bus supporting up to 32 downstream panels. The EP1502 or LP1502 can control up to 64 doors.

Starting in Synergis Softwire 11.3.1 and Security Center 5.10.4.0, LP1502 supports two OSDP readers per port.

  • EP1502:
    • Security Center 5.3 SR1
    • Synergis Softwire 10.0
  • LP1502:
    • Security Center 5.8
    • Synergis Softwire 10.10
EP2500 and LP2500 IP controller with two RS-485 buses, supporting up to 64 doors.
  • EP2500:
    • Security Center 5.3 SR1
    • Synergis Softwire 10.0
  • LP2500:
    • Security Center 5.8
    • Synergis Softwire 10.10
EP4502 and LP4502 IP controller similar to the EP1502 and LP1502, but with an extra RS-485 port and increased credential capacity. The EP4502 and LP4502 support TLS 1.2 protected communications and FICAM Strong Authentication to meet the US Federal FIPS-201 standard.

Starting in Synergis Softwire 11.3.1 and Security Center 5.10.4.0, LP4502 supports two OSDP readers per port.

  • EP4502:
    • Security Center 5.3 SR1
    • Synergis Softwire 10.0
  • LP4502:
    • Security Center 5.8
    • Synergis Softwire 10.10
MR panels Mercury downstream panels (expansion modules) supported with the EP controllers:
MR50
Single reader sub-panel with two inputs and two outputs.
MR51e
Single door, network ready, PoE interface panel.
MR52
Dual reader sub-panel with eight inputs and six outputs.
NOTE: Starting in Synergis Softwire 11.3.1 and Security Center 5.10.4.0, MR50-S3 and MR52-S3 support two OSDP readers per port.
MR16IN
16-input sub-panel.
MR16OUT
16-output sub-panel.
MR62e
Dual door, PoE interface panel.
NOTE: Minimum required versions: Security Center 5.8.1 and Synergis Softwire 10.11
  • MR50, MR51e, MR52, MR16IN, and MR16OUT:
    • Security Center 5.3 SR1
    • Synergis Softwire 10.0
  • MR62e:
    • Security Center 5.8.1.0
    • Synergis Softwire 10.11
Allegion Schlage locks Mercury controllers can also be used with Allegion Schlage AD Series locks. See Supported Allegion Schlage locks in Synergis Softwire 11.4.3.
BEST Wi-Q locks Starting in Synergis Softwire 11.3.1, Mercury LP4502 controllers can also be used with BEST Wi-Q locks. See Supported BEST Wi-Q locks in Synergis Softwire 11.4.3.
SimonsVoss SmartIntego locks Mercury controllers can also be used with SimonsVoss SmartIntego locks. See Supported SimonsVoss locks in Synergis Softwire 11.4.3.
M5 Bridge All Mercury M5 Bridge panels are plug-and-play compatible with your existing Casi Micro5 enclosure and offer one-for-one board replacement with your existing panels.1
M5-IC
Intelligent controller.
M5-2K
4-F2F reader, 10-input, 8-output control device2.
M5-2RP
2-reader control device.
M5-2SRP
2-reader control device with supervised inputs.
M5-8RP
8-reader control device.
M5-20IN
20-input control device.
M5-16DO
16-output control device3.
M5-16DOR
16-output control device.
M5-COM
Power and Comms controller4.
  • Security Center 5.3 SR1
  • Synergis Softwire 10.0
MS Bridge All Mercury MS Bridge panels are direct retrofits of iSTAR Pro panels from Software House. The MS-I8S and MS-R8S panels can also be connected to an EP controller.
MS-ICS
Controller panel that replaces the iSTAR Pro GCM module.
MS-ACS5
Interface panel that replaces the iSTAR Pro ACM module.
MS-I8S
8-input panel that replaces the iSTAR Pro I8 module.
MS-R8S
8-output panel that replaces the iSTAR Pro R8 module.
  • Security Center 5.6
  • Synergis Softwire 10.4

1 When using inputs on the F2F reader or inputs from the interface reader ports, the odd-numbered inputs shown in Config Tool are used for REX, and the even-numbered inputs are used for door contacts.

2 Together, the M5-IC and the M5-2K replace the Casi M2000 enclosure circuit board. There are up to eight enclosures per M5-IC: the first enclosure has one M5-IC plus one M5-2K, and the next seven enclosures have one M5-COM plus one M5-2K.

On an M5-IC with an M5-2K board, inputs 1 to 8 are virtual F2F inputs and outputs 1 to 4 are virtual F2F outputs. Inputs 9 to 18 are physical inputs on the board, and outputs 5 to 12 are relays.

3 Digital outputs (solid-state switches).

4 Used for downstream communication with add-on enclosures with no M5-IC.

5 MS-ACS boards consume two addresses. If the DIP switch settings are set to 0 and 2 with 2 MS-ACS boards connected on the ribbon bus of the MS-ICS, then addresses 0 to 4 are used, and cannot be re-used by other downstream MS or MR boards.