Not all Synergis™ appliance features are supported with the integration of Assa Abloy IP locks.
The Assa Abloy IP lock integration supports the following Synergis™ Appliance Portal and Synergis™ Softwire features. For a description of these
features, see Interface tour of the
Synergis Appliance Portal
.
Synergis™ Appliance Portal and firmware features | Supported |
---|---|
Hardware configuration (pre-staging capability) | |
Manual enrollment (Add hardware dialog box) | See note1 |
Automatic enrollment (Scan button) | Yes |
Property configuration | No |
Configuration cloning (Clone button) | No |
I/O diagnostics (live monitoring of inputs, relays, and readers) | No |
Interface module firmware display | Yes |
Interface module firmware upgrade | Yes |
Double-badge activation | Yes2 |
Access control behavior (Synergis unit-wide settings) 3 | |
Interlock setting (Single door unlock or Single door open) | No |
Do not generate Door open too long events when door is unrestricted | Yes |
Reader setting (Card or PIN or Card only) | Yes |
Maximum PIN length in digits | 64 |
1 You need to pair the IP lock with the Synergis unit.
2 See Enabling passage mode on Assa Abloy IP locks.
3 The door behavior settings are overwritten by the individual door settings configured in Security Center.