Not all Synergis™ appliance features are supported with the integration of Axis controllers.
The Axis controller integration supports the following Synergis™ Appliance Portal and Synergis™ Softwire features. For a description of these
features, see Interface tour of the
Synergis Appliance Portal
.
Synergis™ Appliance Portal and firmware features | Supported |
---|---|
Hardware configuration (pre-staging capability) | |
Manual enrollment (Add hardware dialog box) | Yes |
Automatic enrollment (Scan button) | No |
Property configuration | Yes |
Configuration cloning (Clone button) | Yes |
I/O diagnostics (live monitoring of inputs, relays, and readers) | Yes |
Interface module firmware display | Yes |
Interface module firmware upgrade | Manual1 |
Double-badge activation | Online |
Access control behavior (Synergis unit-wide settings) 2 | |
Interlock setting (Single door unlock or Single door open) | Online |
Do not generate Door open too long events when door is unrestricted | Yes |
Reader setting (Card or PIN or Card only) | Yes |
Maximum PIN length in digits 3 | 16 |
1 The recommended Axis firmware can be upgraded through the Hardware inventory task in Config Tool or by applying the Axis .sfw file as a firmware upgrade through the Synergis™ Appliance Portal.
2 The door behavior settings are overwritten by the individual door settings configured in Security Center.
3 For keypad readers outputting PIN in 4-bit Burst Keypad Mode.