Not all Synergis™ appliance features are supported with the integration of SALTO SALLIS wireless locks.

The SALTO SALLIS wireless lock integration supports the following Synergis™ Appliance Portal and Synergis™ Softwire features. For a description of these features, see Interface tour of the Synergis Appliance Portal .
Synergis™ Appliance Portal and firmware features Supported
Hardware configuration (pre-staging capability)  
Manual enrollment (Add hardware dialog box) Yes
Automatic enrollment (Scan button) Yes
Property configuration Yes
Configuration cloning (Clone button) Yes
I/O diagnostics (live monitoring of inputs, relays, and readers) Partial1
Interface module firmware display Router only
Interface module firmware upgrade No
Double-badge activation No
Access control behavior (Synergis unit-wide settings) 2  
Interlock setting (Single door unlock or Single door open) No
Do not generate Door open too long events when door is unrestricted Yes
Reader setting (Card or PIN or Card only) No3
Maximum PIN length in digits Not applicable

1 Inputs without a sensor attached are not monitored on the I/O diagnostic page.

2 The door behavior settings are overwritten by the individual door settings configured in Security Center.