Not all Security Center access control features are supported with the integration of Assa Abloy IP locks.
- Yes
- Feature is supported by this integration.
- Limited
- Part of the feature is not supported.
- No
- Feature is not supported by this integration.
- Online
- Feature is supported only when the interface module is connected to the Synergis unit.
- Not applicable
- Feature does not apply to this integration.
Feature group | Security Center feature | Supported |
---|---|---|
Door behavior settings (overrides the Synergis unit-wide settings) | Maintenance mode (keep door unlocked and ignore all access events) | PoE only |
Standard grant time | Yes | |
Extended grant time | Yes | |
Entry time (Standard/Extended) 1 | No | |
Door relock - options | Not applicable | |
When door is unlocked by schedule - options | Yes | |
Door held - options | Yes | |
Door forced open - options | Yes | |
Unlock schedules | Yes | |
Request to exit (REX) options | ||
Unlock on REX (On/Off) | No | |
Time to ignore REX after granting access (in seconds) | No | |
Ignore REX events while door is open (On/Off) | No | |
Time to ignore REX after door closes (in seconds) | No | |
Visitor escort and two-person rule | ||
Maximum delay between card presentation (in seconds) | No | |
Enforce two-person rule (On/Off) on Door side | No | |
Manual actions on doors in Security Desk 2 | Manually unlock doors | PoE only |
Reader shunting (activate/deactivate reader) | No | |
Override unlock schedules | Limited3 | |
Live event monitoring in Security Desk 4 | Module running state (Online, Offline) | Yes5 |
AC fail | Not applicable | |
Battery fail (Low battery) | Yes | |
Door open/closed | Limited6 | |
Door locked/unlocked | Limited6 | |
Door forced open | Yes | |
Door held open for too long | Limited7 | |
Duress PIN | No | |
Deadbolt (Secured, Released) | PoE only | |
Key override | No | |
Area restrictions (for secured areas) | Minimum security clearance (part of threat level management) | No8 |
Visitor escort rule (On/Off) | No | |
Interlock | No | |
Antipassback | No | |
Max occupancy | No | |
First-person-in rule | No | |
Elevator control | Elevators | Not applicable |
Zone management | I/O zone | Not applicable |
Hardware zone | Not applicable |
1 Security Center requires an entry sensor to accurately detect entry into an area. In the absence of the entry sensor, Security Center uses the door sensor, and the Entry detected event is generated when the door sensor is triggered. In the absence of both sensors, Security Center generates the Entry assumed event when access is granted.
2 The Synergis unit must be connected to the Access Manager.
3 For WiFi locks, the command is only applied on the next radio contact.
4 No live event from WiFi locks. The events are only available after the next radio contact.
5 WiFi locks are considered offline only after the periodic radio contact plus 5 minutes is missed.
6 Door open and door closed events are generated only with PoE locks.
7 The timeout value set in Config Tool for triggering Door open too long events cannot exceed 4 minutes 15 seconds (or 255 seconds). Any value set higher than 255 seconds is set to 255 seconds on the Synergis™ unit.
8 Security clearance has no effect on the access permissions of cardholders but it does make locks following a Security Center unlock schedule go into a locked state if security clearance is set below 7.