Not all Security Center access control features are supported with the integration of SimonsVoss locks.
- Yes
- Feature is supported by this integration.
- Limited
- Part of the feature is not supported.
- No
- Feature is not supported by this integration.
- Online
- Feature is supported only when the interface module is connected to the Synergis unit.
- Not applicable
- Feature does not apply to this integration.
Feature group | Security Center feature | Supported |
---|---|---|
Door behavior settings (overrides the Synergis unit-wide settings) | Maintenance mode (keep door unlocked and ignore all access events) | No |
Standard grant time | Yes1 | |
Extended grant time | Not applicable | |
Entry time (Standard/Extended) 2 | Not applicable | |
Door relock - options | No | |
When door is unlocked by schedule - options | Yes | |
Door held - options | No | |
Door forced open - options | Not applicable | |
Unlock schedules | Yes | |
Request to exit (REX) options | ||
Unlock on REX (On/Off) | Not applicable | |
Time to ignore REX after granting access (in seconds) | Not applicable | |
Ignore REX events while door is open (On/Off) | Not applicable | |
Time to ignore REX after door closes (in seconds) | Not applicable | |
Visitor escort and two-person rule | ||
Maximum delay between card presentation (in seconds) | Yes4 | |
Enforce two-person rule (On/Off) on Door side | Yes | |
Manual actions on doors in Security Desk 3 | Manually unlock doors | Yes |
Reader shunting (activate/deactivate reader) | No | |
Override unlock schedules | Yes | |
Live event monitoring in Security Desk | Module running state (Online, Offline) | Yes |
AC fail | No | |
Battery fail (Low battery) | Yes | |
Door open/closed | No | |
Door locked/unlocked | No | |
Door forced open | No | |
Door held open for too long | No | |
Duress PIN | No | |
Area restrictions (for secured areas) | Minimum security clearance (part of threat level management) | Not applicable |
Visitor escort rule (On/Off) | Yes | |
Interlock | Not applicable | |
Antipassback | Not applicable | |
Max occupancy | Not applicable | |
First-person-in rule | Not applicable | |
Elevator control | Elevators | Not applicable |
Zone management | I/O zone | Not applicable |
Hardware zone | Not applicable |
1 The maximum supported value is 255 seconds. Values between 26 and 59 seconds are rounded to 1 minute. Values above 60 seconds are rounded to the next minute. For example, 121 seconds is rounded to 3 minutes.
2 Security Center requires an entry sensor to accurately detect entry into an area. In the absence of the entry sensor, Security Center uses the door sensor, and the Entry detected event is generated when the door sensor is triggered. In the absence of both sensors, Security Center generates the Entry assumed event when access is granted.
3 The Synergis unit must be connected to the Access Manager.
4 The minimum value is five seconds. The lock LED blinks when it is ready for the second card to be presented, which is not immediately.