The Axis controller features two tamper inputs that can be monitored in Security Center.

The following are the tamper inputs:
Input Tampered
The input is active when one of the following occurs:
  • Input “IN3” on one of the two reader I/O connectors is active.
  • The front tampering alarm sensor is activated.
  • The back tampering alarm switch is activated.
Input CasingOpen
The input is active when one of the following occurs:
  • The front tampering alarm sensor is activated.
  • The back tampering alarm switch is activated.
The front and back tampering alarms can be disabled by putting a jumper on the respective 2-pin Tampering Alarm Pin Header.
  • Tampering alarm pin header – front (TF)