Supported ASSA ABLOY IP locks in Synergis Softwire 11.5.3 - Synergis Softwire 11.5.3

Synergis™ Softwire Integration Guide 11.5.3

Product
Synergis Softwire
Content type
Guides > Integration guides
Version
11.5
Release
11.5.3
ft:locale
en-US
Last updated
2025-01-23

For ASSA ABLOY IP lock integration, each IP lock is viewed as an interface module.

Synergis™ Softwire 11.5.3 supports the following ASSA ABLOY IP locks:
Brand Name Type Firmware Certification
Corbin Russwin Access 700 PIP1 (Px) PoE   Supported by design
Corbin Russwin Access 700 PIP1 (Cx) PoE 3_0p09_cx_37012 Supported by design
Corbin Russwin Access 700 PWI1 (Cx) Wi-Fi 3_0p09_cx_37012 Supported by design
Corbin Russwin Access 700 PWI1 (Px) Wi-Fi   Supported by design
Corbin Russwin Access 800 IP1 (Sx) PoE   Supported by design
Corbin Russwin Access 800 WI1 (Sx) Wi-Fi   Supported by design
Corbin Russwin IN120 (Cx) Wi-Fi 3_0p10_cx_v40113 Supported by design
Corbin Russwin IN220 (Cx) PoE 3_0p09_cx_37012 Supported by design
SARGENT IN120 (Cx) Wi-Fi 3_0p10_cx_v40113 Certified
SARGENT IN220 (Cx) PoE 3_0p09_cx_37012 Certified
SARGENT Passport 1000 P1 (Cx) PoE 3_0p09_cx_37012 Supported by design
SARGENT Passport 1000 P1 (Px) PoE 3_0n18_px_pfm Certified
SARGENT Passport 1000 P2 (Cx) Wi-Fi 3_0p09_cx_37012 Supported by design
SARGENT Passport 1000 P2 (Px) Wi-Fi 3_0n18_px_pfm Certified
SARGENT Profile Series v.S1 (Sx) PoE 3_0n18_sx_pfm

3_0n18_hx_pfm1

Certified
SARGENT Profile Series v.S2 (Sx) Wi-Fi 3_0n18_sx_pfm

3_0n18_hx_pfm1

Certified

1 Sx controllers running Hx firmware require the Firmware type option to be set to Hx on the Hardware page of the Synergis™ unit in Config Tool.

2 You can’t downgrade from 3_0p09_cx_3701 to any earlier version.